Skip to content

Progression, lighter weeks and breaks

How loads move within and between sessions, when a lighter week is offered, and how VidarFit brings you back after time off.

Guidelines add load once a target is beaten, and adding reps works about as well as adding weight. VidarFit adds the smallest step your equipment allows, never skips one, and starts the next session from your last completed working load at the same prescription (after a first day that ended short at a heavier weight, the last load that made its range), not from an all-time best.

Lighter weeks cut sets, load and effort while keeping exercises and training days, following surveys and consensus work with competitive lifters. Strength is largely kept over a few weeks off and returns quickly, so VidarFit’s return-from-break ladder is deliberately more conservative than measured strength loss. Many of the exact step sizes and thresholds here are VidarFit’s own calibrations; each rule says which.

Rules in this chapter

Product decisionPublished evidenceModerate confidence

Live step up: 15+ reps with 3+ in reserve

During a hypertrophy session, when a completed working set reaches 15 or more reps AND the athlete answered 3 or more reps in reserve, the remaining unlogged sets of that exercise move up one real equipment step, unless that step is more than 20% heavier or the card says the next weight has to wait: then the weight stays. Unanswered effort never triggers an increase.

Published finding

Double progression (add reps, then load) is an effective progression method; ACSM suggests adding load once the target is exceeded by 1–2 reps.

VidarFit's choice

A live step at ≥15 reps with answered RIR ≥3: one equipment step, never on unanswered effort.

Consistent with ACSM's load-increase trigger and with rep-progression evidence; the two-condition trigger guards against noisy RIR reports.

Sources, uncertainty and limitsfor Live step up: 15+ reps with 3+ in reserve
Uncertainty
One equipment step can be a large relative jump on dumbbells or kettlebells (25 → 35 lb is +40%; a 12 → 16 kg kettlebell, about 26 → 35 lb, is +33%); the coarse-step guard holds such jumps until reps have built first.
When data is missing
If the next step does not exist (the athlete's heaviest owned load), hold, and aim for more reps.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. American College of Sports Medicine. American College of Sports Medicine position stand. Progression models in resistance training for healthy adults. Med Sci Sports Exerc. 2009;41(3):687-708.

    Position stand. Supports: Increase load 2–10% when the current workload can be done for 1–2 reps over the desired number.

    PubMed 19204579DOI 10.1249/MSS.0b013e3181915670

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Plotkin D, Coleman M, Van Every D, et al. Progressive overload without progressing load? The effects of load or repetition progression on muscular adaptations. PeerJ. 2022;10:e14142.

    Study. Supports: Progressing reps at a fixed load and progressing load gave similar hypertrophy and strength in trained people over 8 weeks.

    PubMed 36199287PMC9528903DOI 10.7717/peerj.14142

    Identifier verified and claim checked against the abstract on 2026-09-28.

  3. Zourdos MC, Goldsmith JA, Helms ER, et al. Proximity to Failure and Total Repetitions Performed in a Set Influences Accuracy of Intraset Repetitions in Reserve-Based Rating of Perceived Exertion. J Strength Cond Res. 2021;35(Suppl 1):S158-S165.

    Study. Supports: In sets to failure at 70% 1RM (~16 reps), predictions made at 3 RIR were off by ~3.7 reps on average; accuracy was worse further from failure.

    PubMed 30747900DOI 10.1519/JSC.0000000000002995

    Identifier verified and claim checked against the abstract on 2026-09-28.

Product decisionEvidence-informed choiceLow confidence

Live step down: below 8 reps, or 8 at zero in reserve

When a completed hypertrophy working set has fewer than 8 reps, or exactly 8 reps at 0 in reserve (including a 'couldn't finish' set of 8 or fewer), the remaining unlogged sets drop by max(15% of the load, 5 lb) snapped down to available equipment, never below the lightest step. For 3 sessions from a coarse jump, its own day first, a set below 8 reps that ended within the planned reserve holds the load instead. A written card has no live drop, so two sessions under its range reset it by 10%.

Published finding

Reps to failure fall as the load rises toward 1RM, with wide variation between people and exercises; no study tests how much to reduce load after a missed rep target.

VidarFit's choice

A 15% drop (at least 5 lb).

Rough check with conventional practitioner %1RM charts (not independently verified here): an 8-rep-to-failure load is about 80% 1RM; 15% less is about 68%, which such charts put at roughly 12–15 reps to failure, i.e. about 9–12 reps at 3 in reserve, back inside the window. Evidence does not contradict the chosen value.

Sources, uncertainty and limitsfor Live step down: below 8 reps, or 8 at zero in reserve
Uncertainty
Rep-to-load relationships vary widely between people and exercises (large between-person SD in Nuzzo 2024).
When data is missing
If already at the lightest step, hold and suggest an easier variation or assistance.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Nuzzo JL, Pinto MD, Nosaka K, et al. Maximal Number of Repetitions at Percentages of the One Repetition Maximum: A Meta-Regression and Moderator Analysis of Sex, Age, Training Status, and Exercise. Sports Med. 2024;54(2):303-321.

    Meta-analysis. Supports: Reps possible at a given %1RM fall as load rises; the mean REPS~%1RM relationship lets a load change be translated into an expected rep change.

    PubMed 37792272PMC10933212DOI 10.1007/s40279-023-01937-7

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Shimano T, Kraemer WJ, Spiering BA, et al. Relationship Between the Number of Repetitions and Selected Percentages of One Repetition Maximum in Free Weight Exercises in Trained and Untrained Men. J Strength Cond Res. 2006;20(4):819.

    Study. Supports: Repetitions to failure at fixed %1RM differ between exercises and training status (metadata verified via Crossref).

    DOI 10.1519/R-18195.1

    Identifier verified on 2026-09-28; the claim was not checked against the text.

Evidence-informed choiceEngineering assumptionModerate confidence

Where the next session starts

The next session starts from the carry-forward load for the same exercise at the same prescription (same slot rep range and target RIR and, on undulating plans, the same day type), plus one step if that session earned an increase that was not applied (two for a new lifter's lower-body barbell lift that beat its effort target by 2 reps, within 10%). The carry-forward load is the load of the last completed working set of the most recent exposure that was neither a deload nor day-adjusted; a day-adjusted exposure (readiness, pain check-in, train-anyway) can raise it by one step, and lowers it to what it finished on when a set failed or fell under its range, or when it finished under the load it asked for. On a prescription's first session, when the last set fell short at a heavier load than an earlier set that made its range, the carry-forward is the load of the last set that made its range, so a step the first day took and failed isn't the next start. It also comes down the first time back on that lift after more than 3 weeks away: an adjusted session or a deload then brings it to the layoff ladder, or to what was lifted if that was more. When the prescription changes (a goal or slot change, or an undulating day type with no recent exposure), the start is repriced from the athlete's current strength estimate at the new rep target. The layoff ladder applies to the lift's time away, as “Returning after a break: load ceiling ladder” sets it out, or to the longest break from its family since this prescription last ran.

Published finding

Progression research works from the current working load; strength is not static over time; the number of reps possible at a given load varies between people and exercises, so a load translated to a new rep target is an estimate.

VidarFit's choice

Carry-forward per prescription key with a one-step cap, two for new lifters' lower-body barbell lifts; repricing from a conservative recency-weighted estimate only when the prescription changes.

Starts and lighter weeks are never priced from an all-time best. Carrying forward the last completed working load also keeps undulating days and goal changes correct: a volume day of 5 × 5 at 265 lb no longer caps the next heavy day at 270 lb, and a move from 5-rep strength work at 225 lb to an 8–15 hypertrophy slot starts about 10% lighter (about 200 lb), not at 225 lb. A recency-weighted estimate from recent sets is used only when the prescription changes, because carrying the same prescription forward reproduces the live progression exactly and the athlete can check it against their own log.

Sources, uncertainty and limitsfor Where the next session starts
Uncertainty
Rep-to-load conversion by the Epley form varies widely between people and exercises; a repriced start is corrected by the live rules within the first sets. The 0.95 low-confidence factor and the 56-day key age are engineering choices.
When data is missing
No history for the exercise: the weight the person told VidarFit, if any; then a similar-movement estimate × 0.5 (never a machine or a cable for a free weight), else a calibration ramp (a written card keeps its targets: the person picks a heavier weight).
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Plotkin D, Coleman M, Van Every D, et al. Progressive overload without progressing load? The effects of load or repetition progression on muscular adaptations. PeerJ. 2022;10:e14142.

    Study. Supports: Rep and load progression from the current working load both produce adaptation.

    PubMed 36199287PMC9528903DOI 10.7717/peerj.14142

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Bosquet L, Berryman N, Dupuy O, et al. Effect of training cessation on muscular performance: a meta-analysis. Scand J Med Sci Sports. 2013;23(3):e140-9.

    Meta-analysis. Supports: Strength declines with training cessation in a dose-response manner with the duration of cessation.

    PubMed 23347054DOI 10.1111/sms.12047

    Identifier verified and claim checked against the abstract on 2026-09-28.

  3. Nuzzo JL, Pinto MD, Nosaka K, et al. Maximal Number of Repetitions at Percentages of the One Repetition Maximum: A Meta-Regression and Moderator Analysis of Sex, Age, Training Status, and Exercise. Sports Med. 2024;54(2):303-321.

    Meta-analysis. Supports: Reps possible at a given %1RM vary with load, exercise and person, so a load priced for a new rep target is an estimate to be corrected by the live rules.

    PubMed 37792272PMC10933212DOI 10.1007/s40279-023-01937-7

    Identifier verified and claim checked against the abstract on 2026-09-28.

GuidelineProduct decisionEngineering assumptionModerate confidence

Load steps follow the athlete's real equipment

Every load change moves to a load the athlete actually owns or can build (plates, dumbbell pairs, bells, stack pins). An increase takes the smallest owned step above the current load, whatever its relative size, and never skips a step (the only exception is the two-step increase for new athletes' lower-body barbell lifts under the strength progression rule). Reductions snap down. If the gym has a lighter bar, the next card moves to it when a start comes out under the usual bar or a set before the last fell short on it. A coarse-step guard (next owned load more than 20% heavier) is active for the strength rep-range and hypertrophy models: reps build first. Each heavier load is judged by what happened on it: one whose latest try was in range is never held, a step of more than 10% that fell short builds reps before its next try, and after 2 tries it waits until it's lifted, for up to 8 sessions from the first try. A jump of more than 5 kg (about 11 lb) also has to be one the last session's sets say can be lifted for the range.

Published finding

ACSM recommends 2–10% load increases once the target is beaten by 1–2 reps. No study tests what to do when the smallest available increase is larger than that.

VidarFit's choice

Smallest owned step, never skipped. The 2–10% guideline is a preference that real equipment often cannot meet (an empty 20 kg bar to 22.5 kg is +12.5%, 45 to 50 lb is +11%, a 12 to 16 kg kettlebell is +33%), so a single step is always allowed. Coarse-step guard (20% threshold, +5 reps, 3-session hold) on for the strength rep-range and hypertrophy models.

A percentage cap on every increase would block progress entirely on light loads and coarse equipment. The guard limits the ping-pong a coarse jump causes (a 26 → 35 lb kettlebell, reps fall below the range, the drop sends the athlete back to 26 lb). On hypertrophy it replaces the rule of adding one step after 15 or more reps on coarse equipment, which bounced small dumbbells between a load that was easy and one that failed. A jump of more than 5 kg (about 11 lb) has to be one the last session's sets say can be lifted for the range, on strength and muscle-building work alike. A smaller one gets a try once the reps are there, because reps on a light load can't show what a person can lift. On a written card, or a lift held to its own range, that means 3 sessions in a row at the top of the card, left blank or answered at the card's number, or one rep past it on every set, left blank or answered at most one under. A number alone has to show the step can be lifted.

Sources, uncertainty and limitsfor Load steps follow the athlete's real equipment
Uncertainty
The 20% threshold, +5 reps and 3-session hold are engineering choices.
When data is missing
No inventory: default steps above, labeled as assumed until the athlete confirms equipment.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. American College of Sports Medicine. American College of Sports Medicine position stand. Progression models in resistance training for healthy adults. Med Sci Sports Exerc. 2009;41(3):687-708.

    Position stand. Supports: Recommended load increases are 2–10% once the target is exceeded by 1–2 reps.

    PubMed 19204579DOI 10.1249/MSS.0b013e3181915670

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Schoenfeld BJ, Grgic J, Ogborn D, et al. Strength and Hypertrophy Adaptations Between Low- vs. High-Load Resistance Training: A Systematic Review and Meta-analysis. J Strength Cond Res. 2017;31(12):3508-3523.

    Meta-analysis. Supports: Muscle hypertrophy can be equally achieved across a spectrum of loading ranges when sets are taken to failure.

    PubMed 28834797DOI 10.1519/JSC.0000000000002200

    Identifier verified and claim checked against the abstract on 2026-09-28.

GuidelineEngineering assumptionLow confidence

Strength progression: top of the range, then add load

For strength-type slots, when every working set reaches the top of the rep range at or above the target RIR, the next session adds the smallest owned step, whatever its size (new athletes' lower-body barbell lifts may add two steps when every set was at least 2 reps easier than targeted and the two-step jump is no more than 10%). With unknown effort every set needs one rep more than an answered set would, and the next card offers that rep. A written card keeps its reps, so 3 sessions in a row at its top earn the step too, and the card says so. A working set that ends below the range minimum drops the remaining sets by max(10%, 5 lb), snapped down. Two consecutive sessions below the range reset that lift by 10%. On coarse equipment the coarse-step guard applies. A deload doesn't count toward the stall rule, and a day-adjusted exposure counts only when a set fell under its range. A session in range after the reset ends the stall: the new start is what it lifted, or the reset's load if an easier day's card was lighter.

Published finding

Load increases after exceeding a rep target are standard; autoregulating with effort reports is supported.

VidarFit's choice

One owned step per session (two for new athletes' lower-body barbell lifts when that stays within 10%), a 10% live drop below the range at any effort, a 10% stall reset after two sessions, and the coarse-step guard.

The 10% limit applies only to the optional double step. Capping every increase at 10% would make a single step impossible at light loads and on coarse equipment (empty bar +12.5%, 45 → 50 lb +11%, 12 → 16 kg bell +33%) and freeze progress. At 3–6 reps each rep is worth roughly 2.5–4% of 1RM on typical tables, so a 10% drop restores the range without overshooting; 15% (hypertrophy) would be too large here. Dropping below the range at any effort (not only at RIR 0) stops a clearly overloaded slot, such as 7 reps in a 10–15 slot, from holding for two sessions.

Sources, uncertainty and limitsfor Strength progression: top of the range, then add load
Uncertainty
Stall and reset rules come from coaching practice (novice linear progression), not trials.
When data is missing
Missing RIR: increase if every set has one rep more than an answered set would need, or after 3 sessions in a row at the top of a written card; decreases follow reps.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. American College of Sports Medicine. American College of Sports Medicine position stand. Progression models in resistance training for healthy adults. Med Sci Sports Exerc. 2009;41(3):687-708.

    Position stand. Supports: 2–10% load increase when the current load can be lifted for 1–2 reps over the target.

    PubMed 19204579DOI 10.1249/MSS.0b013e3181915670

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Graham T, Cleather DJ. Autoregulation by "Repetitions in Reserve" Leads to Greater Improvements in Strength Over a 12-Week Training Program Than Fixed Loading. J Strength Cond Res. 2021;35(9):2451-2456.

    Study. Supports: RIR-based autoregulation improved strength more than fixed loading (metadata only).

    PubMed 31009432DOI 10.1519/JSC.0000000000003164

    Identifier verified on 2026-09-28; the claim was not checked against the text.

  3. Helms ER, Cross MR, Brown SR, et al. Rating of Perceived Exertion as a Method of Volume Autoregulation Within a Periodized Program. J Strength Cond Res. 2018;32(6):1627-1636.

    Study. Supports: RPE-based stops and load reductions were used to autoregulate volume in powerlifters.

    PubMed 29786623DOI 10.1519/JSC.0000000000002032

    Identifier verified and claim checked against the abstract on 2026-09-28.

Published evidenceEvidence-informed choiceLow confidence

Top set and back-off autoregulation

Powerlifting top sets are performed at the target RIR; if the top set is 2+ reps easier than targeted, one more top set one step heavier is allowed. Back-off sets use the top-set load × the back-off fraction and stop early if RIR falls below the slot minimum. The next session adds a step when the top set hit the top of its range at or above target RIR. On undulating plans only the heavy day runs the top set; volume and light days progress with the strength rep-range model on their own day-type key.

Published finding

Top set plus RPE-stopped back-offs is a studied autoregulation method in powerlifters.

VidarFit's choice

One optional extra top set; back-offs stop when effort gets too high.

Mirrors the studied protocol with conservative limits.

Sources, uncertainty and limitsfor Top set and back-off autoregulation
Uncertainty
Small samples of trained powerlifters.
When data is missing
Missing top-set RIR: back-offs at the lower fraction; no increase next session.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Helms ER, Cross MR, Brown SR, et al. Rating of Perceived Exertion as a Method of Volume Autoregulation Within a Periodized Program. J Strength Cond Res. 2018;32(6):1627-1636.

    Study. Supports: Top set at a prescribed RPE, optional second top set if RPE too low, then back-off sets stopped when target RPE reached.

    PubMed 29786623DOI 10.1519/JSC.0000000000002032

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Androulakis-Korakakis P, Michalopoulos N, Fisher JP, et al. The Minimum Effective Training Dose Required for 1RM Strength in Powerlifters. Front Sports Act Living. 2021;3:713655.

    Study. Supports: Back-off sets at ~80% of the single's load may add strength gains.

    PubMed 34527944PMC8435792DOI 10.3389/fspor.2021.713655

    Identifier verified and claim checked against the abstract on 2026-09-28.

Engineering assumptionProduct decisionLow confidence

Progression for assisted, bodyweight, band and timed work

Assisted (counterweight) movements reverse the load rules: under 8 reps adds max(15%, 5 lb) assistance; 15+ reps at 3+ in reserve removes one step; zero assistance is graduation. Bodyweight and band work add one rep per successful session up to 5 above the window, then suggest a harder variation. Timed holds add 5 s per success up to a ceiling, then add owned load.

Published finding

Rep progression is effective; no direct evidence exists for assisted-machine or timed-hold step sizes.

VidarFit's choice

Mirror the hypertrophy thresholds for assistance; +1 rep and +5 s steps for bodyweight and holds.

Consistency with the main rule; athletes understand one pattern.

Sources, uncertainty and limitsfor Progression for assisted, bodyweight, band and timed work
Uncertainty
Step sizes are heuristics.
When data is missing
Unknown bodyweight: bodyweight work progresses by reps only and is excluded from e1RM.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Plotkin D, Coleman M, Van Every D, et al. Progressive overload without progressing load? The effects of load or repetition progression on muscular adaptations. PeerJ. 2022;10:e14142.

    Study. Supports: Adding repetitions at a fixed load is a valid progression method.

    PubMed 36199287PMC9528903DOI 10.7717/peerj.14142

    Identifier verified and claim checked against the abstract on 2026-09-28.

Published evidenceEvidence-informed choiceModerate confidence

How much periodization each experience level gets

New athletes use simple session-to-session double or linear progression with no planned variation. Most 'some' policies add planned deloads. Experienced strength athletes, powerlifting athletes ('some' and experienced) and experienced powerbuilding athletes use weekly undulation of the main lift: each exposure in a week takes the next day type (volume, light, heavy) in a fixed order that ends the week on the heavy day. Hypertrophy, general fitness and hybrid never undulate. Experienced powerlifters get an optional taper.

Published finding

Periodization helps maximal strength, especially undulating models in trained people, and does not change hypertrophy. In powerlifters, a weekly order of hypertrophy, power, then strength days produced larger bench press gains than hypertrophy, strength, power. RPE-based loading inside an undulating week worked at least as well as percentage loading.

VidarFit's choice

Weekly undulation for experienced strength-type goals and powerlifting 'some', ordered volume → light → heavy; day-type values are VidarFit choices inside each slot's envelope; taper for experienced powerlifting only (low confidence).

The benefit of undulation is concentrated in trained lifters and in strength outcomes. The heavy-day-last order follows Zourdos 2016. RIR targets per day type match the RPE-based loading that performed at least as well as percentages (Helms 2018, Front Physiol). Keying starts by day type stops a volume day from capping the heavy day.

Sources, uncertainty and limitsfor How much periodization each experience level gets
Uncertainty
Day-type reps, RIR and set counts are VidarFit choices; the undulation-order study was small (18 men, 6 weeks). Taper parameters rest on a review with limited data.
When data is missing
Unknown experience uses 'new'.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Williams TD, Tolusso DV, Fedewa MV, et al. Comparison of Periodized and Non-Periodized Resistance Training on Maximal Strength: A Meta-Analysis. Sports Med. 2017;47(10):2083-2100.

    Meta-analysis. Supports: Periodized training had a moderate advantage over non-periodized training for 1RM; undulating models were more favorable; untrained people improved more overall.

    PubMed 28497285DOI 10.1007/s40279-017-0734-y

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Moesgaard L, Beck MM, Christiansen L, et al. Effects of Periodization on Strength and Muscle Hypertrophy in Volume-Equated Resistance Training Programs: A Systematic Review and Meta-analysis. Sports Med. 2022;52(7):1647-1666.

    Meta-analysis. Supports: Volume-equated periodization improved 1RM more than non-periodized training, with undulating > linear only in trained people; no effect on hypertrophy.

    PubMed 35044672DOI 10.1007/s40279-021-01636-1

    Identifier verified and claim checked against the abstract on 2026-09-28.

  3. Travis SK, Mujika I, Gentles JA, et al. Tapering and Peaking Maximal Strength for Powerlifting Performance: A Review. Sports (Basel). 2020;8(9):125.

    Review. Supports: Evidence on how to taper and peak maximal strength is limited; practitioners rely on trial and error.

    PubMed 32917000PMC7552788DOI 10.3390/sports8090125

    Identifier verified and claim checked against the abstract on 2026-09-28.

  4. Zourdos MC, Jo E, Khamoui AV, et al. Modified Daily Undulating Periodization Model Produces Greater Performance Than a Traditional Configuration in Powerlifters. J Strength Cond Res. 2016;30(3):784-791.

    Study. Supports: In 18 college-aged male powerlifters training 3 days a week for 6 weeks, a weekly order of hypertrophy, power, then strength days gave larger bench press 1RM gains than hypertrophy, strength, power (squat and deadlift 1RM did not differ; effect sizes favored the heavy-day-last order for squat and bench).

    PubMed 26332783DOI 10.1519/JSC.0000000000001165

    Identifier verified and claim checked against the abstract on 2026-09-28.

  5. Helms ER, Byrnes RK, Cooke DM, et al. RPE vs. Percentage 1RM Loading in Periodized Programs Matched for Sets and Repetitions. Front Physiol. 2018;9:247.

    Study. Supports: In resistance-trained men following a daily undulating squat and bench program 3 times a week for 8 weeks, RPE-based load selection was at least as effective as percentage-1RM loading, with a possible small strength advantage.

    PubMed 29628895PMC5877330DOI 10.3389/fphys.2018.00247

    Identifier verified and claim checked against the abstract on 2026-09-28.

Published evidenceEvidence-informed choiceLow confidence

What a deload week does

A deload lasts 7 days: sets halved (at least 1 per movement), load 0.85 × the carry-forward load of each prescription key (the load the next normal session would start from, without an earned step; never an estimate when that load exists), target RIR raised by 1, same exercises, day types and frequency. At least 21 days between deloads.

Published finding

Deloads are near-universal in practice and usually reduce volume, load and effort while keeping exercise selection; full cessation for a week may slightly cost strength.

VidarFit's choice

Reduced-load deload, not a week off.

Matches reported practice and avoids the small strength cost seen with full cessation.

Sources, uncertainty and limitsfor What a deload week does
Uncertainty
No trial compares deload magnitudes; values mirror survey practice.
When data is missing
A key without a recent exposure: 0.85 × its repriced start. No strength history for the exercise at all: the normal no-history fallbacks (similar-movement estimate × 0.5 or a calibration ramp), which are already conservative, without the 0.85 factor.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Rogerson D, Nolan D, Androulakis Korakakis P, et al. Deloading Practices in Strength and Physique Sports: A Cross-sectional Survey. Sports Med Open. 2024;10(1):26.

    Study. Supports: Competitive athletes deloaded for ~6.4 days every ~5.6 weeks, reducing reps, sets and load and increasing RIR while keeping frequency and exercise selection.

    PubMed 38499934PMC10948666DOI 10.1186/s40798-024-00691-y

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Bell L, Strafford BW, Coleman M, et al. Integrating Deloading into Strength and Physique Sports Training Programmes: An International Delphi Consensus Approach. Sports Med Open. 2023;9(1):87.

    Consensus statement. Supports: Delphi consensus definition: a period of reduced training stress to mitigate fatigue and promote recovery.

    PubMed 37730925PMC10511399DOI 10.1186/s40798-023-00633-0

    Identifier verified and claim checked against the abstract on 2026-09-28.

  3. Coleman M, Burke R, Augustin F, et al. Gaining more from doing less? The effects of a one-week deload period during supervised resistance training on muscular adaptations. PeerJ. 2024;12:e16777.

    Study. Supports: One week of full training cessation mid-program did not change hypertrophy but slightly reduced strength gains versus continuous training.

    PubMed 38274324PMC10809978DOI 10.7717/peerj.16777

    Identifier verified and claim checked against the abstract on 2026-09-28.

  4. Bell L, Darragh IAJ, Travis SK, et al. A Practical Approach to Deloading: Recommendations and Considerations for Strength and Physique Sports. Strength Cond J. 2026;48(4):413-423.

    Review. Supports: Practical deloading recommendations for strength and physique sports (metadata only).

    DOI 10.1519/SSC.0000000000000910

    Identifier verified on 2026-09-28; the claim was not checked against the text.

Evidence-informed choiceProduct decisionLow confidence

When a deload is offered

A deload is offered (never forced) when: two or more lifts have stalled for two sessions at once; 3 of the last 5 answered check-ins are in the moderate or severe band; pain in the same region is reported in 2 consecutive sessions; or the athlete asks. A single stalled lift on a strength card or a written card gets a 10% reset instead.

Published finding

Performance stalls, soreness and joint aches are the common practical deload triggers; self-reported well-being tracks training load.

VidarFit's choice

Four triggers, all resulting in an offer with a reason.

Uses signals VidarFit actually collects, and leaves the choice with the athlete: a deload is offered, never imposed.

Sources, uncertainty and limitsfor When a deload is offered
Uncertainty
Trigger thresholds are practitioner-style heuristics.
When data is missing
Skipped check-ins do not count toward the low-readiness trigger.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Rogerson D, Nolan D, Androulakis Korakakis P, et al. Deloading Practices in Strength and Physique Sports: A Cross-sectional Survey. Sports Med Open. 2024;10(1):26.

    Study. Supports: Athletes deloaded when performance stalled or with increased soreness or joint aches, often combining planned and autoregulated approaches.

    PubMed 38499934PMC10948666DOI 10.1186/s40798-024-00691-y

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Saw AE, Main LC, Gastin PB. Monitoring the athlete training response: subjective self-reported measures trump commonly used objective measures: a systematic review. Br J Sports Med. 2016;50(5):281-91.

    Review. Supports: Subjective well-being worsens with increased training load and improves when load decreases.

    PubMed 26423706PMC4789708DOI 10.1136/bjsports-2015-094758

    Identifier verified and claim checked against the abstract on 2026-09-28.

  3. Hooper SL, Mackinnon LT, Howard A, et al. Markers for monitoring overtraining and recovery. Med Sci Sports Exerc. 1995;27(1):106-12.

    Study. Supports: Self-reported well-being ratings predicted staleness and taper improvement in swimmers.

    PubMed 7898325

    Identifier verified and claim checked against the abstract on 2026-09-28.

Evidence-informed choiceLow confidence

Scheduled deloads by experience

New athletes never get scheduled deloads in any goal (trigger-based only). Scheduled cadence in loading weeks between deloads: hypertrophy, strength, powerbuilding and hybrid: 'some' 8, experienced 6; powerlifting: 'some' 6, experienced 6; general fitness: 'some' none (triggers only), experienced 8. Triggers can offer a deload at any level.

Published finding

Scheduled breaks show no benefit in the one trial available; experienced athletes still deload every ~4–8 weeks in practice.

VidarFit's choice

No scheduled deload for new athletes or general-fitness 'some'; a 6–8 week cadence otherwise, shorter for heavier or higher-volume goals.

Beginners' gains outpace fatigue; general-fitness 'some' trains at 2–3 in reserve with modest budgets; powerlifting 'some' already trains top sets at 1–2 in reserve, so it uses the experienced cadence; the 6–8 week range mirrors reported practice (about 5.6 ± 2.3 weeks).

Sources, uncertainty and limitsfor Scheduled deloads by experience
Uncertainty
Cadence is practice-based rather than trial-based.
When data is missing
Unknown experience uses 'new' (no scheduled deload).
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Coleman M, Burke R, Augustin F, et al. Gaining more from doing less? The effects of a one-week deload period during supervised resistance training on muscular adaptations. PeerJ. 2024;12:e16777.

    Study. Supports: A mid-program week off did not improve outcomes versus continuous training (and slightly reduced strength) in trained people.

    PubMed 38274324PMC10809978DOI 10.7717/peerj.16777

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Rogerson D, Nolan D, Androulakis Korakakis P, et al. Deloading Practices in Strength and Physique Sports: A Cross-sectional Survey. Sports Med Open. 2024;10(1):26.

    Study. Supports: Experienced competitive athletes deloaded about every 5.6 ± 2.3 weeks.

    PubMed 38499934PMC10948666DOI 10.1186/s40798-024-00691-y

    Identifier verified and claim checked against the abstract on 2026-09-28.

Product decisionEvidence-informed choiceLow confidence

Returning after a break: load ceiling ladder

When a lift has not been trained for more than 21 days, its first exposure is capped at a fraction of its carry-forward load (the last completed working load of a normal session): 1.0 up to 21 days, linearly to 0.85 at 56 days, linearly to 0.50 at 365 days, and 0.50 beyond. Time away is from the lift's family: the same main movement pattern on the same kind of equipment and load, leaving out conditioning lifts. A stretch with nothing in the family is a break, whatever came back after it. A lift the plan rested while its family kept training counts half its own days, a lift pain took out counts all of them, and a lift with several kinds of day comes back this way on each.

Published finding

Strength is well kept for about 3 weeks and declines gradually thereafter, and is regained quickly; protection against soreness from new work fades between 6 and 12 months.

VidarFit's choice

A fixed ladder by time away, as above.

The ladder is more conservative than measured strength loss, deliberately: it also covers lost tissue tolerance, technique and the repeated-bout protection that fades by 12 months. Evidence supports the 21-day hold and does not contradict the rest.

Sources, uncertainty and limitsfor Returning after a break: load ceiling ladder
Uncertainty
The 0.85 and 0.50 points are heuristics; they intentionally over-reduce for most people.
When data is missing
If no exposure of the lift has a completed working set (for example a warm-up-only session), the start comes from the fallbacks in “Where the next session starts” (reprice from the pricing e1RM, similar movement, or a calibration ramp); a prescribed load is never treated as performed.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Bosquet L, Berryman N, Dupuy O, et al. Effect of training cessation on muscular performance: a meta-analysis. Scand J Med Sci Sports. 2013;23(3):e140-9.

    Meta-analysis. Supports: Strength declines with training cessation in a dose-response manner, more in older and inactive people.

    PubMed 23347054DOI 10.1111/sms.12047

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Mujika I, Padilla S. Detraining: loss of training-induced physiological and performance adaptations. Part I: short term insufficient training stimulus. Sports Med. 2000;30(2):79-87.

    Review. Supports: Short-term detraining (<4 weeks) reverses fibre-size gains but strength declines are limited.

    PubMed 10966148DOI 10.2165/00007256-200030020-00002

    Identifier verified and claim checked against the abstract on 2026-09-28.

  3. Ogasawara R, Yasuda T, Ishii N, et al. Comparison of muscle hypertrophy following 6-month of continuous and periodic strength training. Eur J Appl Physiol. 2013;113(4):975-85.

    Study. Supports: 3-week breaks between 6-week training blocks led to similar hypertrophy and strength after 24 weeks as continuous training.

    PubMed 23053130DOI 10.1007/s00421-012-2511-9

    Identifier verified and claim checked against the abstract on 2026-09-28.

  4. Halonen EJ, Gabriel I, Kelahaara MM, et al. Does Taking a Break Matter-Adaptations in Muscle Strength and Size Between Continuous and Periodic Resistance Training. Scand J Med Sci Sports. 2024;34(10):e14739.

    Study. Supports: Strength and size lost over a 10-week break were regained rapidly on retraining.

    PubMed 39364857DOI 10.1111/sms.14739

    Identifier verified and claim checked against the abstract on 2026-09-28.

  5. Bickel CS, Cross JM, Bamman MM. Exercise dosing to retain resistance training adaptations in young and older adults. Med Sci Sports Exerc. 2011;43(7):1177-87.

    Study. Supports: Strength gained in 16 weeks was largely retained through 32 weeks of detraining in young and older adults.

    PubMed 21131862DOI 10.1249/MSS.0b013e318207c15d

    Identifier verified and claim checked against the abstract on 2026-09-28.

  6. Nosaka K, Sakamoto K, Newton M, et al. How long does the protective effect on eccentric exercise-induced muscle damage last? Med Sci Sports Exerc. 2001;33(9):1490-5.

    Study. Supports: Protection against eccentric muscle damage lasted at least 6 months and was absent at 12 months.

    PubMed 11528337DOI 10.1097/00005768-200109000-00011

    Identifier verified and claim checked against the abstract on 2026-09-28.

Product decisionEngineering assumptionLow confidence

Re-entry window and copy

After an athlete-level break, the first 6 sessions (or 56 days) start weekly volume at the budget minimum and ramp to target over 3 weeks; a lift idle for more than 56 days holds (no increase) on its first exposure. Copy says there is not enough recent information and invites the athlete to lower the load, never to add weight.

Published finding

Retraining after breaks restores strength and size quickly.

VidarFit's choice

6 sessions / 56 days bounded window.

Ends at a fixed point, so a return period never drags on. The design is carried over from the earlier version of VidarFit.

Sources, uncertainty and limitsfor Re-entry window and copy
Uncertainty
Window length is a heuristic.
When data is missing
If session history is sparse the window ends at 56 days regardless.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Halonen EJ, Gabriel I, Kelahaara MM, et al. Does Taking a Break Matter-Adaptations in Muscle Strength and Size Between Continuous and Periodic Resistance Training. Scand J Med Sci Sports. 2024;34(10):e14739.

    Study. Supports: Strength and size lost during a 10-week break were regained rapidly on retraining.

    PubMed 39364857DOI 10.1111/sms.14739

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Spiering BA, Mujika I, Sharp MA, et al. Maintaining Physical Performance: The Minimal Dose of Exercise Needed to Preserve Endurance and Strength Over Time. J Strength Cond Res. 2021;35(5):1449-1458.

    Review. Supports: Strength and size can be maintained for up to 32 weeks with 1 session and 1 set per exercise per week if relative load is kept (younger populations).

    PubMed 33629972DOI 10.1519/JSC.0000000000003964

    Identifier verified and claim checked against the abstract on 2026-09-28.

Evidence-informed choiceEngineering assumptionVery low confidence

Returning to running after a break

Days since the last run (logged, or reported when nothing is logged) set the re-entry: under 7 days resume; 7–13 days 70% of prior weekly volume with 1 easy-only week; 14–27 days 50% with 1 easy-only week; 28–89 days 40% with 2 easy-only weeks; 90 days or more, or no running history, restart the beginner run/walk progression followed by 4 easy-only weeks. Prior weekly volume is the mean of the 4 weeks before the last run, from logs or from the athlete's report (x 0.8 when reported).

Published finding

Aerobic fitness declines measurably within 3 weeks and more by 8 weeks.

VidarFit's choice

Stepped volume factors with easy-only weeks.

Volume factors are engineering assumptions chosen to be clearly below the fitness loss, because musculoskeletal tolerance (injury risk) is the binding limit and is not measured.

Sources, uncertainty and limitsfor Returning to running after a break
Uncertainty
No trial defines return-to-run volumes. The multipliers have no published source and remain assumptions.
When data is missing
Last run known but prior volume unknown: ask for the usual week; if unanswered, the run/walk start. Nothing logged or reported: the run/walk start, with running habituation 'unknown'.
Not designed for
under 18; pregnancy-specific or postpartum programming; clinical rehabilitation or supervised medical exercise
Sources
  1. Coyle EF, Martin WH 3rd, Sinacore DR, et al. Time course of loss of adaptations after stopping prolonged intense endurance training. J Appl Physiol Respir Environ Exerc Physiol. 1984;57(6):1857-64.

    Study. Supports: In trained endurance athletes VO2max fell 7% in the first 21 days of inactivity and stabilized 16% below trained values by 56 days.

    PubMed 6511559DOI 10.1152/jappl.1984.57.6.1857

    Identifier verified and claim checked against the abstract on 2026-09-28.

  2. Mujika I, Padilla S. Detraining: loss of training-induced physiological and performance adaptations. Part I: short term insufficient training stimulus. Sports Med. 2000;30(2):79-87.

    Review. Supports: Short-term detraining rapidly lowers VO2max and blood volume in highly trained athletes.

    PubMed 10966148DOI 10.2165/00007256-200030020-00002

    Identifier verified and claim checked against the abstract on 2026-09-28.

Not medical advice. These rules describe how VidarFit plans training; they are not a diagnosis or treatment.